General
Specification
Terminal assignment
Dimension
Download
Manual Pulse Generator – JOG handwheel
A tool for quick configuration of a material base (G54, G55 …), tool magazine (tool length offset), as well as for manual machining or fast manual rides (requires CSMIO-MPG module available separately or in the MPG Kit). Connection with CSMIO-MPG is extremely simple and shouldn’t take more than 5 minutes, even for inexperienced users.
How to run it?
- Fasten the module on a DIN rail
- Place the DB25 plug of the JOG handwheel in the CSMIO-MPG module socket.
- Connect the CAN bus with the included DB9 tape
- Connect 24V DC power.
- Connect E-STOP circuit to terminals E1 and E2 (order of the connections is not important). Terminals E1 and E2 are pins of the handwheel E-STOP button.
ISMM2080 | – | 001 | 100 | B | – | 5 | L |
Series | Sequence Number | Number of Pulses | Output Signals | Supply Voltage | Output Circuit |
Specification
ELECTRICAL SPECIFICATION | |
Output wave | Square wave |
Output signals | A,B, (Line driver output A,A(_),B,B(_), phase) |
Current consumption | ≤100mA |
Response Frequency | 0~20KHz |
Output phase difference | 90° ± 45° |
Supply voltage | 5VDC, 12 VDC |
Signal level | VH ≥ 85%Vcc, VL ≤ 0.3V |
Number of pulses | 100 |
Output circuit | Open collector NPN, Push pull, Line driver, Voltage |
MECHANICAL SPECIFICATION | |
Signal position | 2kind |
Speed without sealing | 500 rmp |
Starting torque w/o sealing | ≤2.0x 10-2 ~6.0x 10-2 Nm (+25°C) |
Shock resistance | 980m/s2, 6ms, 2 times each on XYZ |
Vibration proof | 50m/s2, 10~200Hz, 2 hours each on XYZ |
Working life | MTBF≥ 10000h (+25°C, 2000rpm) |
Weight | Appr. 740g (incl. 1.5 meter cable) |
ENVIRONMENTAL SPECIFICATION | |
Working humidity | 30~85% (No condensation) |
Storage temperature | -30°C ~85°C |
Working temperature | -10°C ~7O°C |
Protection class | IP54 |
Terminal assignment
ELECTRICAL SPECIFICATION OF SELECTION SWITCH | ||||
Switch load | 0.4VA | Max. voltage | 25V | |
Circuit width | 0.1-50mA | |||
ELECTRICAL SPECIFICATION OF CONTROL SELECTION | ||||
Connection Point | AC Max. load | AC220VV 0.5A | ||
DC Max. load | DC24V1A | |||
ELECTRICAL SPECIFICATION OF STOP SWITCH | ||||
Connection Point | AC Max. load | AC220V0.5A | ||
DC Max. load | DC30V1A |