Tag Archives: CNC

CAN extension for CSMIO/IP controllers and CSMIO modules

Many users very often need much longer manual handwheel cable than originally provided. Their first idea is to extend the multi-wire cable of a handwheel. It’s a very bad idea as extending the cable is time-consuming and requires special caution and care making new connections. Moreover, the extended cable is much more exposed to interference what may cause uncontrolled moves of a machine when using the handwheel. The best solution in this thought situation is to extend a CAN bus and not the handwheel cable. 

In this situation, a CSMIO-MPG module should be installed as close to an operator as so the handwheel cable length is enough for you. Connect a CSMIO/IP controller and the CSMIO-MPG module with CAN bus extension cord. Below we present the diagram of CAN bus extension cord for CSMIO/IP-S controller and CSMIO-MPG module but it can be used with all CAMIO/IP controllers and CSMIO modules. 

  Open the PDF file for larger drawing details

[Source:] The diagram was created by CS-Lab’s Technical Support section for CSMIO/IP users.

11 February 2019

CSMIO/IP-M controller vs AASD driver, DQ542MA, TB6600 and YKD2405M stepper drivers

1. Connection diagram of CSMIO/IP-M controller and AASD driver

   Open the PDF file for larger drawing details

2. Connection diagram of CSMIO/IP-M controller and TB6600 stepper driver

   Open the PDF file for larger drawing details

3. Connection diagram of CSMIO/IP-M controller and YKD2405M stepper driver

    Open the PDF file for larger drawing details 

4. Connection diagram of CSMIO/IP-M controller and DQ542MA stepper driver

    Open the PDF file for larger drawing details

[Source:] The diagram was created by CS-Lab’s Technical Support section for CSMIO/IP users.

28 January 2019